CRC ADOS F3 Non-Drip Contact Adhesive 500ml
Available
CRC ADOS F3 is a solvent-based, thixotropic, high strength contact adhesive with a polychloroprene (Neoprene) base. CRC formulated it to be non-spill and non-drip, and its data sheet says the gel suits vertical and ceiling applications and porous surfaces such as Gib board, including the end grain of particle board.
CRC's product page lists laminated plastics, hardboard and aluminium to wood, brick or metal; PVC cloth, plastics and rubber to wood, concrete or cardboard; felt to wood, cardboard or metal; and acoustic ceiling tiles to wood or concrete. It comes in a 500ml pack. The safety data sheet classifies it as a highly flammable liquid that may damage fertility or the unborn child.
Where this product is used
- Vertical and ceiling applications
- Porous surfaces such as Gib board, including the end grain of particle board
- Laminated plastics, hardboard and aluminium to wood, brick or metal
- PVC cloth, plastics and rubber to wood, concrete or cardboard
- Felt to wood, cardboard or metal
- Acoustic ceiling tiles to wood or concrete
Features
- Thixotropic gel, formulated by CRC to be non-spill and non-drip
- Solvent-based polychloroprene (Neoprene) contact adhesive
- Tested to -20°C to +80°C (CRC data sheet)
- CRC says it has good resistance to heat, water, acids and alkalis
- Coverage 3-4 m2 per litre of bond area
- Bond is immediate on contact once both coated surfaces are tacky (10-20 minutes)
- Can be reactivated with heat or solvent (CRC data sheet)
Key specifications
| Specification | Detail |
|---|---|
| Product type | Solvent-based, thixotropic, high strength contact adhesive (CRC data sheet) |
| CRC product number | 8020 |
| Pack | 500ml |
| Base | Polychloroprene (Neoprene) |
| Form and colour | Thixotropic gel; honey (data sheet); viscous yellow liquid (SDS) |
| Coverage | 3-4 m2 per litre bond area |
| Open time and working time | Solvent should have evaporated between 10-20 minutes; working time 10-20 minutes |
| Tested temperature range | -20°C to +80°C |
| Storage | Indoor temperature between 5°C and 20°C |
| Flash point | Below 0°C (SDS); highly flammable |
| Dangerous goods (SDS) | UN 1133, ADHESIVES containing flammable liquid, Class 3, Packing Group II; Hazchem 3YE |
| Hazard classification (SDS) | Signal word Danger. H225, H304, H315, H319, H336, H360, H372. Poison schedule S5 |
| Source | CRC Industries (Aust) technical data sheet version 08/2019 and safety data sheet 13/12/24 (revision 1.2); CRC Australia product page (crcindustries.com.au) |
Selecting the right option
F3 is the gel. For a liquid (non-gel) contact adhesive from the same range see CRC ADOS F2 Multi-Purpose Contact Adhesive. For a spray-applied adhesive see CRC ADOS Multi-Purpose Spray Adhesive.
Using it
CRC's directions: surfaces must be thoroughly clean and dry, and pre-wiped. Do not stir, as this will break the gel structure. Do not thin, as this will adversely affect performance.
Use a straight edge, notched trowel or the scraper provided to apply an even layer to both surfaces. Bond when tacky (10-20 minutes, tacky but not transferring to a clean finger). Contact is immediate, so position accurately, then apply maximum overall instant pressure, for example with a hand roller.
CRC's data sheet gives no shelf life for F3 and says to store it indoors at a temperature between 5°C and 20°C.
Storage and handling
CRC says to store indoors at a temperature between 5°C and 20°C. The data sheet gives no shelf life for F3.
Limits and safety
Classified on the SDS as a highly flammable liquid. Signal word Danger. H225: highly flammable liquid and vapour. H304: may be fatal if swallowed and enters airways. H315: causes skin irritation. H319: causes serious eye irritation. H336: may cause drowsiness or dizziness. H360: may damage fertility or the unborn child. H372: causes damage to organs through prolonged or repeated exposure. Poison schedule S5. Transport: UN 1133, adhesives containing flammable liquid, Class 3, Packing Group II. The SDS lists acetone, toluene and light aliphatic solvent naphtha, each at 10 to 30%. Read the safety data sheet before use.
Frequently asked questions
Can CRC ADOS F3 be used on vertical or overhead surfaces?
CRC's data sheet describes it as a thixotropic non-drip gel that suits vertical and ceiling applications and porous surfaces such as Gib board.
Should CRC ADOS F3 be stirred or thinned?
No. CRC says not to stir it because that breaks the gel structure, and not to thin it because that adversely affects performance.
How is CRC ADOS F3 applied?
CRC says to use a straight edge, notched trowel or the scraper provided, apply an even layer to both surfaces, wait 10-20 minutes until tacky, then press together with maximum instant pressure.
What temperature range is CRC ADOS F3 tested to?
CRC's data sheet states it was tested to -20°C to +80°C.
How much area does CRC ADOS F3 cover?
CRC gives coverage of 3-4 m2 per litre of bond area.
Is CRC ADOS F3 hazardous?
Yes. The SDS (13/12/24, revision 1.2) classifies it as a highly flammable liquid, signal word Danger, and lists H360 (may damage fertility or the unborn child) and H372. It is UN 1133, Class 3, Packing Group II.
Related products
See also: CRC ADOS F2 Multi-Purpose Contact Adhesive, CRC ADOS Multi-Purpose Spray Adhesive, CRC Ultra High Strength Spray Aerosol Adhesive 8180 - 550ml, CRC ADOS MS High Performance Adhesive Sealant.
Couldn't load pickup availability